Fantech has developed the HP Series fans
specifically to suit the higher pressure capability requirements needed in Radon
Mitigation applications. Most Radon mitigators who previously used the
Fantech FR series fans have switched to the new HP Series.
Experts all agree that radon is everywhere. A naturally occurring radioactive
gas, Radon in low concentrations is harmless. In todays better insulated homes
however, radon can accumulate to harmful levels. Your first step in determining
the radon level of your home is to test your home. Test kits can be purchased at
a number of locations in your town or city. (If you have difficulty, contact
your local EPA office and they will assist you).
Once you have tested your home and find that you
have dangerous or elevated amounts of radon present you need to consider radon
mitigation. In your selection of a contractor make sure he is offering Fantech
radon mitigation fans as part of your solution.
|
Fantech HP Series Fans Provide the Solutions to meet the challenges of Radon
applications: |
 |
Housing:
- UV resistant, UL listed durable plastic
- UL Listed for use in commercial
applications
- Factory sealed to prevent leakage
- Watertight electrical terminal box
- Approved for mounting in wet locations -
i.e. outdoors
Motor:
- Totally enclosed for protection
- High efficiency EBM motorized impeller
- Automatic reset thermal overload
protection
- Average life expectancy of 7-10 years
under continuous load conditions
Reliability:
- Five year full factory warranty
- Over 1,000,000 successful radon
installations worldwide
|
| Model |
Watts |
0† |
.50† |
.75† |
1.0† |
1.25† |
1.5† |
Max.
Pres. |
| HP 2133 |
14-20 |
134 |
68 |
23 |
- |
- |
- |
0.84† |
| HP 2190 |
60-85 |
163 |
126 |
106 |
81 |
60 |
35 |
1.93† |
| HP 220 |
85-152 |
344 |
260 |
226 |
193 |
166 |
137 |
2.46† |
Radon
Application Diagram 1
Radon
Application Diagram 2
Shipping Dimensions: 12" x 12" x 10"
Shipping Weight: 8 lbs |