The QC CL-6000RF inline whole house fan can quietly and efficiently cool your home and attic.
This whole house fan works by pulling cooler air from the outside, and pushing hot air out of your attic, allowing you to run your air conditioner less often while keeping your home comfortable.
The primary benefit of the QC CL-6000RF is that it runs quietly. This whole house fan installs very easily by mounting it in the attic, suspended from the rafters.
By having the installation done this way, it
reduces the sound level of the fan.
Features & Benefits:
Download the Quiet Cool Whole House Fan User Manual
Motor Voltage: | 120 VAC, 60Hz |
Energy Use: | 769 Watts High/560 Watts Low |
Air Flow: | 5665 CFM High/4289 CFM Low |
Speeds: | 2 |
Duct Diameter: | 22" |
Duct Length: | 9 feet |
Motor Head Diameter: | 22 1/2" |
Motor Head Length: | 13 1/2" |
Dampers: | Barometric Pressurized R5 Dampers |
Ceiling Rough Opening: | 14 1/4" x 36 1/4" |
Removable Grill Outside Dimension: | 16" x 38" |
Controls: | Wireless RF Control Kit Included |
Covers up to 2833 square feet | |
Requires 7.56 square feet of net attic venting. Fits between 16 or 24 inch on center joists. |
Installers/Contractors Please Call For More
Information about how the QuietCool Fans can increase your sales to your own
customers.
100% Satisfaction Guaranteed.
Backed By Our 30 Day Money Back Guarantee.
We stand behind our products 100%
How to Find Out How Much Net
Free Venting Area You Have in Your Home:
1. Measure All the Vents You Find In Your Home
If you were to measure (length x width) of each vent in your homes attic/roof,
you would have a ball park idea of how much roof and attic venting your home
has.
2. Measure In Inches, Then Convert to Square Feet
Take The Total Area Of Your Vents In Inches And Convert To Sq. Ft By Dividing By
144
3. If Your Vents Are Screened – Take Your Total Area and Cut It In Half!
Since most vents are screened, which can obstruct 1/2 of the air flowing out of
the – once you have your gross total area of venting, multiply that number by .5
to get your Net Free Area Of Venting.
Example: If we take one 12″ x 12″ gable end vent and multiply the length
(12″) by the width (12″) we would have a total of 144 square inches of venting.
To convert to sq. ft. we would divide by 144 (since there are 144 sq. inches in
one square foot). When we divide 144/144 we see that equals 1 sq. ft. But since
our vent is screened, we would take our 1 sq. ft and cut it in half. That leave
us with .5 sq. ft of net free venting.